Strona 1 - A73x addWAVE

A73x addWAVE User Guide Valid for A731, A732, A733 and A733GSM RTUs Release 2.0 and higher Rel. 2.3 / September 2006

Strona 3 - Table of Contents

Using the A73x RTU 2 Using the A73x RTU The A73x series of remote telemetry units (RTUs) is part of the A730 series. For testing purposes, you shou

Strona 4

Installing the RTU Fig. 1: addWAVE RTU (top) Fig. 2: addWAVE RTU (bottom) 2.2 Installing the RTU The following restrictions apply: • In general,

Strona 5 - Table of Contents

Using the A73x RTU 2.3 Special notes for the A733GSM/GPRS RTU The A733GSM/GPRS RTU is based on a GSM module which employs a GSM cellular network to

Strona 6

Special notes for the A733GSM/GPRS RTU Fig. 4: Installing the SIM card in the A733GSM/GPRS RTU 2. Locate the SIM card holder and open it by slidin

Strona 7 - 1 Introduction

Using the A73x RTU #gsmstat 26142 gsmstat GSM modem on: Yes SIM card found: Yes PIN set: Yes PIN accepted: Yes Sleepmode O

Strona 8 - 1.3 Conventions

Special notes for the A733GSM/GPRS RTU Set/configure the following parameters through a terminal connection to enable GPRS connection to your ISP: GP

Strona 9

Using the A73x RTU Configuring the RTU GPRS Connection settings Use the following commands to define the intervals the RTU will wake up and connect

Strona 10

Field Installation Fig. 5: LED Tool Note: The LED tool is a blind plug to be plugged into the POWER connector. Follow these steps to install an

Strona 11 - 2 Using the A73x RTU

Using the A73x RTU 2.5 More about the LED tool The LED tool allows you to rapidly check the status of an A73x RTU. After you insert the LED tool in

Strona 12 - 2.2 Installing the RTU

ADCON TELEMETRY GmbHINKUSTRASSE 24A-3400 KLOSTERNEUBURGAUSTRIATEL: +43-2243-38280-0FAX: +43-2243-38280-6http://www.adcon.ate-mail: [email protected] ADCO

Strona 13

Configuring an A73x RTU in the addVANTAGE software Modem in GPRS network: 3 seconds off, half a second on with short blinks in the off periods. TCP

Strona 14

Using the A73x RTU (samples/15 min) No No sensors 0.85 132 Low No sensors 2.8 40 Heavy No sensors 5 22 Low 3 4.2 26 Low 15 6.3 17 Heavy

Strona 15

Maintaining and servicing the RTU Fig. 7: Unplugging the PCB Connector 3. Unscrew the four screws of the plastic cover that holds the battery pack

Strona 16

Using the A73x RTU 23

Strona 18 - Fig. 5: LED Tool

Performing Advanced Functions 3 Performing Advanced Functions With the appropriate knowledge, you can configure the A73x devices in the field by u

Strona 19 - 2.5 More about the LED tool

Understanding connectors Cabling 1Cabling 2Cabling 3Switched BatteryDigital I/OPulseCounterGround1234567 Fig. 9: Pins on an I/O Connector (Top View)

Strona 20 - 2.7.1 The RTU battery

Performing Advanced Functions ShortBattery (5,6 to 10V)12345+- Fig. 11: A73x Connection with External Battery To use the internal battery with a d

Strona 21 - 2.7.2 Changing the battery

Serial communication protocol 3.3 Serial communication protocol This protocol is based on a master sending commands and a node answering; the whole c

Strona 22 - Fig. 8: A733 Battery Pack

Performing Advanced Functions 3.4 Using terminal commands Following is a list of available commands and an explanation of their use. Note: You ca

Strona 23 - Using the A73x RTU

Table of Contents Table of Contents 1 Introduction ...7 1.1 About the A73x R

Strona 24

Using terminal commands REMARKS GET/SET. Not applicable to the A733GSM/GPRS. REMOTE Yes, SET only. EXAMPLE FREQ 433925000 25000 9193 FREQ 0 # FREQ

Strona 25 - 3.1 Understanding connectors

Performing Advanced Functions SLOT  CAUTION Changing these parameters might adversely affect the ability of the device to operate for extended p

Strona 26 - 3.1.2 The POWER Connector

Using terminal commands REMOTE Yes, SET only. EXAMPLE PMP 65 72 9193 PMP 0 # PMP 9193 PMP 65 72 0 # ANLG AVAILABLE FOR A731 A733A732 A733GSM DESCRI

Strona 27

Performing Advanced Functions Code Description Parameters Returns instructed to store the arithmetic average of all sampled values. 0101 SSMCA

Strona 28

Using terminal commands Code Description Parameters Returns 1110 ENOL – Enable Notify if Out of Limits. The channel num-ber and the limit values

Strona 29 - 3.4 Using terminal commands

Performing Advanced Functions EXAMPLE For RSM ANLG 0 9999 ANLG 0 5 5 5 5 5 5 5 5 4 4 5 5 0 # For SSMAA (on channel 4) ANLG 68 9999 ANLG 68 0 # Fo

Strona 30 - A731 A733A732 A733GSM

Using terminal commands 17 the value from the RTU’s internal battery voltage sensor (raw values are in the range of 0 to 4095, which describe volt

Strona 31

Performing Advanced Functions • dd mm yyyy is the date • hh mm ss is the time • si is the size of the frame (21 for frame type 37, 13 for frame

Strona 32 - Channel Number

Using terminal commands The remote version is limited to a single frame. An example of such a command is given below: 9999 DATA 9999 30/9/1999 14:50:

Strona 33

Performing Advanced Functions 9193 FDEV 0 # INFO AVAILABLE FOR A731 A733A732 A733GSM DESCRIPTION Returns various status information. PARAMETER Non

Strona 34

Table of Contents TIME...29 FREQ ...

Strona 35

Using terminal commands 5 for A723 6 for A440 7 for A733 GSM 8 for A731 9 for A732 • slot and samples are the actual values programmed by using the

Strona 36

Performing Advanced Functions Code Description Parameters Returns 0001 RDDR – Read Data Direction Register. This command reads the whole 16-bi

Strona 37 - Fig. 16: The Digibyte

Using terminal commands Code Description Parameters Returns number ERROR). 1100 MFR – Monostable function, start with the specified bit in OFF s

Strona 38

Performing Advanced Functions For RDDR: PORT 16 9193 PORT 16 0 0 # For ENOPC: PORT 112 9193 PORT 112 0 # For RPNNER: PORT 128 9193 PORT 128 0 1 0 #

Strona 39 - ARAMETER None

Using terminal commands TX 1 9193 TX 0 # TX 5 9193 TX 0 # B AVAILABLE FOR A731 A733A732 A733GSM DESCRIPTION Sends a broadcast frame. PARAMETERS None

Strona 40

Performing Advanced Functions PARAMETERS None. RETURNS The current version. REMARKS GET only. REMOTE No. EXAMPLE VER 9193 VER 1.0.17 0 # Note: T

Strona 41

Using terminal commands 12225 sdi AWmVd 3 0 M0 0x9 0 M2 0x20 7 M5 0x1 0 OK # DATASDI AVAILABLE FOR A731 A733A732 A733GSM DESCRIPTION Returns a sl

Strona 42 - XAMPLE For RDP:

Performing Advanced Functions I/O D Cabling 3 SDI count SDI offset SDI available SDI data block Fig. 18: Frame 60,61 (left) a

Strona 43

Using terminal commands SDA AVAILABLE FOR A731 A733A732 A733GSM DESCRIPTION Sets/returns the maximum delay for waiting awake (i.e. out of sleep mode

Strona 44

Performing Advanced Functions REMARKS SET only. Valid for the A733GSM/GPRS RTU only. REMOTE No. EXAMPLE GSMPIN 1234 29000 GSMPIN 0 # GSMPUK AVAIL

Strona 45

Table of Contents 4 Specifications ... 57 5 APPENDIX ...

Strona 46

Using terminal commands DESCRIPTION Sets/returns the GPRS operator network’s Access Point Name parameter. PARAMETERS The GPRS operator network’s Ac

Strona 47 - Fig. 19: The Digibyte

Performing Advanced Functions # GPRSHOST AVAILABLE FOR A731 A733A732 A733GSM DESCRIPTION Sets/returns the IP address of the A840 Telemetry Gateway

Strona 48

Using terminal commands EXAMPLE GPRSDNS1 29000 GPRSDNS1 123.34.56.34 0 # GPRSDNS1 35.123.33.44 29000 GPRSDNS1 0 # GPRSSECRET AVAILABLE FOR A731 A733

Strona 49

Performing Advanced Functions GPRSCONNALIGN AVAILABLE FOR A731 A733A732 A733GSM DESCRIPTION Sets/returns the connection setup alignment point in t

Strona 50

Notifications 3.5 Notifications Notifications are frames sent asynchronously by devices that are otherwise slaves. The notifications are received by

Strona 51

Performing Advanced Functions 13 — no more space for descriptors (too many devices) 14 — no more records for the specified device 15 — temporary co

Strona 53

Specifications 4 Specifications The A733 was intended to fulfill the specification of the EN 300 220-1, and ETSI 300 113, as well as the FCC Part 9

Strona 54 - 3.6 Returned errors list

Returned errors list Parameter Min Typ Max Unit Analog Inputs Accuracy 0.1 % Analog Input Range 0 2.5 V Digital I/O 4 (A733 and A733GSM

Strona 55 - 3.6.5 Notifications

Specifications Receiver (Not Valid for A733GSM/GPRS) Sensitivity (12 dB S/S+N) -118 dBm Image Frequency Attenuation (1st IF=45MHz) -70

Strona 57 - 4 Specifications

Upgrading an older A733 GSM 5 APPENDIX 5.1 Upgrading an older A733 GSM If you want to update an older A733 addWAVE GSM RTU for use with GPRS, first m

Strona 58

APPENDIX Then enter at+wopen=1 and you should get OK If you get any other message than "OK,” the IP stack needs to be enabled. You

Strona 60 - 5 APPENDIX

Index 6 Index A A440 ...20 A730MD ...12 A733GSM Communi

Strona 61

Index Connector I/O Connector...26 Power Connector ...26 D DATA...

Strona 62

Introduction 1 Introduction This manual explains the hardware aspects of Adcon’s A733, A732, A731, and A733GSM/GPRS remote telemetry units (hereaft

Strona 63 - 6 Index

Compliance Statement and Warnings 1.2 Compliance Statement and Warnings The A73x addWAVE (radio version) must not be used with any antenna other than

Strona 64

Introduction  CAUTION Indicates that you may get unexpected results if you don’t follow the instructions. Cautions appear before the information